A comparative study of immunoglobulin IgM and rheumatoid factor IgMRF in solution by small-angle X-ray scattering

V. V. Volkova, V. A. Lapukb, A. I. Toropovac, E. Yu. Varlamovad, E. V. Shtykovaa, K. A. Demboa, V. P. Timofeeve

a A.V. Shubnikov Institute of Crystallography, FSRC ‘Crystallography and Photonics', Russian Academy of Sciences, Moscow, Russian Federaion
b N.D. Zelinsky Institute of Organic Chemistry, Russian Academy of Sciences, Moscow, Russian Federation
c D.V. Skobeltsyn Institute of Nuclear Physics, M.V. Lomonosov Moscow State University, Moscow, Russian Federation
d Hematology Research Center, Russian Academy of Medical Sciences, Moscow, Russian Federation
e M.M. Shemyakin–Yu.A. Ovchinnikov Institute of Bioorganic Chemistry, Russian Academy of Sciences, Moscow, Russian Federation

Аннотация: The shapes of rheumatoid factor molecules calculated from X-ray small-angle solution scattering data suggest that the peripheral Fab regions of rheumatoid factor in solution are more flocculent because of a higher flexibility of Fab domains.

Язык публикации: английский

DOI: 10.1016/j.mencom.2012.05.017