RUS  ENG
Full version
JOURNALS // Avtomatika i Telemekhanika // Archive

Avtomat. i Telemekh., 2011 Issue 10, Pages 4–18 (Mi at2285)

This article is cited in 10 papers

Topical issue

Self-tuning PID/I controller

A. G. Aleksandrov, M. V. Palenov

Trapeznikov Institute of Control Sciences, Russian Academy of Sciences, Moscow, Russia

Abstract: A self-tuning controller based on the method of frequency identification and intended for controlling plants with time-varying parameters under arbitrary bounded exogenous disturbances was proposed. The impact of the harmonic frequencies of the test signal on the results of identification over a prescribed time was studied. Methods to choose frequencies and an algorithm to adjust the amplitudes of the harmonics of the test signal were proposed. The duration of the identification parameters of the plant model is determined automatically depending on the intensity of the exogenous disturbance and the desired relative accuracy of identification. The results of experimental studies of the proposed controller demonstrating its efficiency were presented.

Presented by the member of Editorial Board: B. T. Polyak

Received: 14.04.2011


 English version:
Automation and Remote Control, 2011, 72:10, 2010–2022

Bibliographic databases:


© Steklov Math. Inst. of RAS, 2025