Abstract:
A procedure of determining the system transfer function coefficients is described when a disturbance of an arbitrary form is fed to the input and the input and output signals are recorded. The system is assumed stable and its transfer function to be of an arbitrary (possibly transcendental) form. Some multiple integrals of the recorded transfer functions have to be determined.