Abstract:
Complexity of a circuit for correction of constant failures and faults in combinational units, CU, is estimated with a certain active slack of monitoring time [1] in the unit to be corrected. The slack is shown to permit simplification of the correcting circuit. The lower estimate of complexity is given. The proposed correction method leads to a correcting unit of asymptotically minimal complexity.