RUS  ENG
Full version
JOURNALS // Fundamentalnaya i Prikladnaya Matematika // Archive

Fundam. Prikl. Mat., 2005 Volume 11, Issue 8, Pages 165–174 (Mi fpm920)

This article is cited in 4 papers

Accuracy testing of control for an astronaut saver

V. A. Sadovnichiia, V. V. Aleksandrov, S. S. Lemaka, S. S. Pozdnyakovb

a M. V. Lomonosov Moscow State University
b RD&PE "Zvezda"

Abstract: The problem of testing quality of control algorithms for an astronaut saver, i.e., a device for rescue of astronauts (DRA), is considered. The suggested testing simulator is based on a dynamic stand (centrifuge CF-18). This stand enables simulation of conditions for astronaut sensory conflict of weightlessness. An appropriate algorithm of weightlessness simulation, used at the Cosmonaut Training Center (Russia) subjected to expertize of many astronauts and would-be astronauts is described. Testing accuracy of DRA control implements a procedure of maximin testing. The worst parameters of DRA obtained as a solution to the maximin problem are used at the second stage of testing, as inputs for a program simulating DRA motion and visual environment near an orbital station.

UDC: 531.3:681.5.01


 English version:
Journal of Mathematical Sciences (New York), 2007, 147:2, 6662–6667

Bibliographic databases:


© Steklov Math. Inst. of RAS, 2024