Analysis of the Tesla transformer operation at the first half-wave of the output voltage taking into account ohmic losses

E. I. Pal'chikovab, A. M. Ryabchunab

a Lavrentyev Institute of Hydrodynamics of Siberian Branch of the Russian Academy of Sciences, Novosibirsk
b Novosibirsk State University

Abstract: The speed and efficiency of the Tesla transformer at the first half-wave of the output voltage are studied as a function of the Q factors of the circuits and their coupling factor. Calculated results and experimental data are considered. It is shown that for given Q factors, there is an optimal value of the coupling factor providing the highest efficiency, which can be calculated and for which designers should work.

Received: 17.06.2015


 English version:
Technical Physics, 2016, 61:6, 919–923