Operating stability of a self-breakdown spark-gap frequency switch rated at a voltage of 300 kV and a switched power of up to 450 J

B. M. Koval'chuka, Yu. D. Korolevab, E. V. Kumpyaka, O. B. Frantsa, I. A. Shemyakina

a Institute of High Current Electronics, Siberian Branch of the Russian Academy of Sciences, Tomsk
b Tomsk Polytechnic University

Abstract: A test bench for studying two-electrode spark gaps rated at a voltage of 300 kV and a pulse repetition rate of up to 10 Hz and operating in air at elevated pressure. The typical time of pulse charging of a capacitive storage in the bench equals about 100 $\mu$s. The object of investigation is a spark gap the operating stability of which at a level of 10% of the rate voltage is achieved by initiating a corona discharge at the prebreakdown stage. It is shown that unstable operation is due to the accumulation of nitrogen oxides in the gap. To maintain the oxide content at an acceptable level, continuous gas purging is applied and necessary gas flow rates are estimated.

Received: 14.02.2014


 English version:
Technical Physics, 2014, 59:12, 1874–1880

Bibliographic databases:


© Steklov Math. Inst. of RAS, 2025