RUS  ENG
Full version
JOURNALS // Pisma v Zhurnal Tekhnicheskoi Fiziki // Archive

Pisma v Zhurnal Tekhnicheskoi Fiziki, 2020 Volume 46, Issue 1, Pages 36–38 (Mi pjtf5226)

This article is cited in 2 papers

The magnetron synchronization band

Yu. D. Chernousovab, I. V. Shebolaevab, I. M. Ikryanova, V. A. Bolotovb, Yu. Yu. Tanashevb, L. È. Medvedevc, R. V. Voskoboinikovc

a Institute of Chemical Kinetics and Combustion, Siberian Branch of the Russian Academy of Science
b Boreskov Institute of Catalysis SB RAS, Novosibirsk
c G I. Budker Institute of Nuclear Physics, Siberian Branch of the Russian Academy of Sciences, Novosibirsk

Abstract: The magnetron synchronization band is measured. For measurements, a microwave generator based on a magnetron of a household oven with a wide range of changes in pulsed and average microwave power was used. Synchronization in a specified band is shown to require an order of magnitude lower microwave power than follows from recent publications. A method for measuring the resonator parameters at a large coefficient of coupling with the line is presented.

Keywords: magnetron, synchronization, quality factor, coupling coefficient.

Received: 26.09.2019
Revised: 26.09.2019
Accepted: 04.10.2019

DOI: 10.21883/PJTF.2020.01.48862.18051


 English version:
Technical Physics Letters, 2020, 46:1, 31–33

Bibliographic databases:


© Steklov Math. Inst. of RAS, 2025