Abstract:
A generator design with a pulse energy of more than 1 MJ connected to an external constant voltage source with limited current strength and power is proposed. The power supply of an active-inductive load is calculated numerically and analytically. Generator parameters for pulse-frequency operation are determined. Results of an experimental study of a small-sized transformer generator are given that confirm the efficiency of this generator and the validity of the method for calculating its characteristics.
Keywords:generator, inductive storage, transformer, switch, current pulse, active load.