RUS  ENG
Full version
JOURNALS // Prikladnaya Mekhanika i Tekhnicheskaya Fizika // Archive

Prikl. Mekh. Tekh. Fiz., 2019 Volume 60, Issue 3, Pages 218–224 (Mi pmtf453)

This article is cited in 4 papers

Pulse X-ray device based on combined helical generator

E. I. Pal'chikovab, A. V. Dolgikhab, V. V. Klypinab, A. M. Ryabchunab, M. S. Samoilenkoa

a Lavrentyev Institute of Hydrodynamics of Siberian Branch of the Russian Academy of Sciences, Novosibirsk, 630090, Russia
b Novosibirsk National Research State University, Novosibirsk, 630090, Russia

Abstract: A prototype of a pulsed X-ray apparatus with and operating voltage of 600–800 kV based on a combined helical generator has been developed and tested. Compared to the classical helical generator, the total length of the helical winding is increased by adding a single-bus line, which allows matching of the wave propagation time along the helical generator line to the oscillation period in the generator with a Tesla transformer. It is shown that the proposed transformer has high efficiency. A theoretical model describing the operation of the combined generator is proposed.

Keywords: helical generator, pulsed x-ray device, source of high-voltage pulses.

UDC: 621.386.1, 621.373, 621.314.21

Received: 11.10.2018
Revised: 11.10.2018
Accepted: 29.10.2018

DOI: 10.15372/PMTF20190322


 English version:
Journal of Applied Mechanics and Technical Physics, 2019, 60:3, 586–591

Bibliographic databases: