N. V. Zavyalov, V. S. Gordeev, S. Yu. Puchagin, A. L. Mozgovoi, A. V. Grishin, K. V. Strabykin, D. O. Mansurov, M. A. Moiseevskikh, E. S. Berdnikov

Institute of Experimental Physics (VNIIEF), Russian Federation Nuclear Center, Sarov, 607188, Russia

Abstract: This paper presents the results of measurements of the generation parameters of the Gamma-4 electrophysical facility designed to generate high-power bremsstrahlung pulses with a duration of $\approx$ 50 ns. Five shots of the Gamma-1 accelerator were performed, in which the bremsstrahlung exposure dose was measured at a distance of 20, 30, and 60 cm from the accelerator target. It is shown that the experimental data correspond to the radiation field of a point cosine source with a relative error of 13%. The spatial distribution of the bremsstrahlung exposure dose of the Gamma-4 facility was reconstructed taking into account the spatial orientation of the irradiators. The bremsstrahlung exposure doses at a distance of 15 cm from the modules targets are presented.

Keywords: electrophysical facility, vacuum pinch-diode, target, bremsstrahlung, exposure dose.

UDC: 539.1.03(621.384.6+533.9.07:533.952)

Received: 22.12.2014