Kvantovaya Elektronika, 2022 Volume 52, Number 4,Pages 386–390(Mi qe18023)
Laser frequency standards
Comparison of field shifts in an atomic clock based on the effect of coherent population trapping in 87Rb atoms under modulation of laser pump current at frequencies of 3.4 and 6.8 GHz
Abstract:
Experimental parameters of the resonance of coherent population trapping (CTP) on D1 line in 87Rb and light shifts are compared under modulation of the laser pump current at frequencies of 3.4 and 6.8 GHz. Reproducibility of the parameters of a laser with a vertical cavity needed for long-term stability of an atomic clock is considered. The instabilities of atomic CPT-clock obtained for 1 s are 1.2 × 10–11 and 3 × 10–12 for frequencies of 3.4 GHz and 6.8 GHz, respectively.
Keywords:coherent population trapping, atomic clock, 87Rb, modulation of laser pump current.