RUS  ENG
Full version
JOURNALS // Kvantovaya Elektronika // Archive

Kvantovaya Elektronika, 2002 Volume 32, Number 6, Pages 490–494 (Mi qe2229)

This article is cited in 11 papers

Active media

A study of a singlet-oxygen generator with a twisted aerosol flow

A. A. Adamenkov, B. A. Vyskubenko, S. P. Il'in, I. M. Krukovskii

Federal State Unitary Enterprise "Russian Federal Nuclear Center — All-Russian Research Institute of Experimental Physics", Sarov, Nizhny Novgorod region

Abstract: The results of a study of a singlet-oxygen generator (SOG) with a twisted aerosol flow are presented. The output parameters of the generator obtained in experiments exceed the corresponding characteristics reported earlier in the literature. The maximum chemical efficiency of the reactor amounts to ~70%. The flux density of the electron energy stored by the excited oxygen molecules in the reaction zone is above 1.5 kJ cm-2 s-1. The measured singlet-oxygen yield is ~60% at a pressure of 100 Torr. Adding a buffer gas (N2) to chlorine ensures an increase in the outlet pressure up to 250 Torr without a decrease in the singlet-oxygen yield. The utilisation of chlorine under such conditions exceeds 95%. The SOG design with a twisted flow ensures atmospheric pressure of the waste solution at the reactor outlet, thus significantly simplifying the development of a system for liquid recycling.

PACS: 42.55.Ks, 82.20.-w

Received: 23.01.2002


 English version:
Quantum Electronics, 2002, 32:6, 490–494

Bibliographic databases:


© Steklov Math. Inst. of RAS, 2024