RUS  ENG
Full version
JOURNALS // Kvantovaya Elektronika // Archive

Kvantovaya Elektronika, 2004 Volume 34, Number 12, Pages 1084–1095 (Mi qe2749)

This article is cited in 6 papers

Optical metrology and quantum frequency standards

Use of cold cesium atoms in quantum frequency standards

Yu. S. Domnin, G. A. Elkin, A. V. Novoselov, V. N. Baryshev, L. N. Kopylov, Yu. M. Malyshev, V. G. Pal'chikov

Institute of Time and Space Metrology, Federal State Unitary Enterprise "National Research Institute of Physicotechnical and Radiotechnical Measurements" (IMVP, FGUP VNIFTRI), Mendeleevo, Moscow Region

Abstract: The results of studies devoted to the development of a new generation quantum frequency standard, a cesium fountain, are presented. The experimental data obtained upon manipulation and detection of cold atoms are analysed. The cooling of cesium atoms down to about 2 μK is demonstrated experimentally. The populations of hyperfine-structure components of cesium atoms are calculated by the method of adiabatic passage for different microwave pulses.

PACS: 42.62.Eh, 32.80.Pj, 45.50.Vk, 32.60.+i

Received: 30.06.2004
Revised: 05.10.2004


 English version:
Quantum Electronics, 2004, 34:12, 1084–1095

Bibliographic databases:


© Steklov Math. Inst. of RAS, 2024