A. S. Boreyshoab, A. B. Barkanb, D. N. Vasil'evb, I. M. Evdokimovb, A. V. Savinb

a Lasers Sistems Ltd., St.-Petersburg
b Baltic State Technical University "Voenmech", St. Petersburg

Abstract: Methods of increasing the efficiency of low-pressure chemical oxygen–iodine lasers (COILs) with transsonic injection of molecular iodine, in which nitrogen is used as a buffer gas, are studied. A two-layer gas-dynamic model is used for a parametric analysis of physicochemical processes occurring in the transsonic iodine injector and in the COIL resonator, including mixing and generation of radiation. The 3D-RANS computer simulation software is used to study the flow structures resulting from an injection of iodine-containing flow into the transsonic zone of the oxygen nozzle. Experiments with a 10-kW modified laser have resulted in a chemical efficiency of 31.5% for a lasing power of 13.5 kW. The results of experimental studies of the cryosorption COIL exhaust system are presented.

PACS: 42.55.Ks, 42.60.By, 42.60.Lh

Received: 16.09.2004
Revised: 22.03.2005


 English version:
Quantum Electronics, 2005, 35:6, 495–503