RUS  ENG
Full version
JOURNALS // Kvantovaya Elektronika // Archive

Kvantovaya Elektronika, 1996 Volume 23, Number 12, Pages 1111–1114 (Mi qe878)

This article is cited in 4 papers

Laser applications and other topics in quantum electronics

Absolute measurements of the frequency of an He—Ne/CH4 standard over a decade

Yu. S. Domnin, L. N. Kopylov, A. N. Malimon, V. P. Tenishev, P. S. Shumyatskii

All-Russian Scientific Research Institute of Physical-Technical and Radiotechnical Measurements, Mendeleevo, Moscow region

Abstract: Measurements carried out on a laser multiplication chain at the All-Russia Scientific-Research Institute of Physicotechnical and Radio Engineering Measurements made it possible to improve the precision of determination of the frequencies of laser standards recommended for reproducing the unit of length. This investigation showed that the long-term drift of the dimensionless combination of the atomic constants g1α2(me/mp)1/2 did not exceed 10–12 per year (g1 is the gyromagnetic ratio of the proton, α is the fine-structure constant, and me and mp are the masses of an electron and a proton).

PACS: 06.20.Fn, 06.30.Ft, 42.62.Eh

Received: 01.01.1996


 English version:
Quantum Electronics, 1996, 26:12, 1081–1084

Bibliographic databases:


© Steklov Math. Inst. of RAS, 2024