Development and investigation of a two-phase loop thermosiphon with a flat evaporator at different slope angles

V. I. Dmitrin, Yu. F. Maidanik

Institute of Thermal Physics, Ural Branch, Russian Academy of Sciences, Ekaterinburg

Abstract: We present the results of the development and experimental studies of a two-phase loop thermosiphon with a flat evaporator and ethanol as the working fluid. We investigated the thermal characteristics of the device within the temperature range of $20$$80^{\circ}$C under the heat loads of $10$$120$ W, a filling ratio of $40\%$, and slope angles within the range of $0^{\circ}$$90^{\circ}$. The device is functional at all of the studied slope angles. The maximum heat load of 120 W was reached at the slope angle of $90^{\circ}$. Here, the average temperature of the evaporator surface was within $70^{\circ}$C and the maximum thermal resistance was equal to $0.41^{\circ}$C/W.

UDC: 536.24

Received: 03.03.2016
Accepted: 08.11.2016

DOI: 10.7868/S0040364418010118


 English version:
High Temperature, 2018, 56:1, 92–97