RUS  ENG
Full version
JOURNALS // Teplofizika vysokikh temperatur // Archive

TVT, 2013 Volume 51, Issue 5, Pages 764–768 (Mi tvt139)

This article is cited in 3 papers

Heat and Mass Transfer and Physical Gasdynamics

Estimation of the influence of temperature pulses on piezoelectric pressure gauge readings

Yu. P. Ivochkin, Yu. A. Zeigarnik, S. N. Vavilov, S. A. Kovalev

Joint Institute for High Temperatures, Russian Academy of Sciences, Moscow, Russia

Abstract: The results of the pressure pulsations measurements connected with the process of the vapor films explosive destruction near heated bodies were analyzed. It was stated that under such conditions false pressure pulses are generated. It was experimentally shown and approved by numerical calculations that such interference may be caused by pressure pulsations due to thermal interaction of the piezotransducers used in the experiments with the high-temperature fragments of vapor. The mechanism of the false pressure pulses generation process caused by the thermal deformation of the membrane that affects the pressure sensor (piezoelectric crystal) was described.

UDC: 531.787

Received: 27.12.2012

DOI: 10.7868/S0040364413050104


 English version:
High Temperature, 2013, 51:5, 690–694

Bibliographic databases:


© Steklov Math. Inst. of RAS, 2024