RUS  ENG
Full version
JOURNALS // Teplofizika vysokikh temperatur // Archive

TVT, 2017 Volume 55, Issue 2, Pages 255–261 (Mi tvt9006)

This article is cited in 13 papers

Heat and Mass Transfer and Physical Gasdynamics

The temperature recovery factor in a boundary layer on a permeable plate

A. I. Leont'ev, V. G. Lushchik, M. S. Makarova

Lomonosov Moscow State University, Institute of Mechanics

Abstract: A numerical investigation of the boundary layer on a permeable wall in a supersonic gas flow was performed using a differential turbulence model. Temperature recovery factors were obtained for a series of Prandtl numbers and gas suction or injection in a wide range of the permeability factor from critical injection to asymptotic suction. With the example of air injection into a supersonic air flow, two methods for determining the temperature of a heat-insulated permeable wall are considered. The first is to solve the problem with a boundary condition of zero heat flux to the wall. The second is similar to an experimental method when the temperature of the gas injected at a section along the plate length becomes equal to the wall temperature. The heat-insulated wall temperatures and temperature recovery factors obtained by these two methods for injection below the critical one are close to each other. In case of critical injection, these two methods yield different results.

UDC: 533.6

Received: 29.09.2015
Accepted: 22.12.2015

DOI: 10.7868/S0040364417020089


 English version:
High Temperature, 2017, 55:2, 246–252

Bibliographic databases:


© Steklov Math. Inst. of RAS, 2024